Abstract
Because of the limits of wearable needle-type or microdialysis-based enzymatic sensors in clinical use, fully implantable glucose monitoring systems (IGMS) represent a promising alternative. Long-term use reducing impact of invasiveness due to implantation, less frequent calibration needs because of a more stable tissue environment around the sensor and potential easier inclusion in a closed-loop insulin delivery system are the expected benefits of IGMS. First experiences with subcutaneous and intravenous IGMS have been recently collected in pilot studies. While no severe adverse events have been reported, biointerface issues have been responsible for the failures of IGMS. Tissue reactions around implanted subcutaneous devices and damages of intravenous sensors due to shearing forces of blood flow impaired IGMS function and longevity. In functioning systems, accuracy of glucose measurement reached satisfactory levels for average durations of about 120 days with subcutaneous IGMS and 259 days with intravenous sensors. Moreover, sensor information could help to improve time spent in normal glucose range when provided to patients wearing subcutaneous IGMS and allowed safe and effective closed-loop glucose control when intravenous sensors were connected to implanted pumps using intra-peritoneal insulin delivery. These data could open a favourable perspective for IGMS after improvement of biointerface conditions and if compatible with an affordable cost.
Keywords: Diabetes mellitus, Continuous blood glucose monitoring, Glucose sensors, Implantable devices, Closed-loop insulin delivery
Current Diabetes Reviews
Title: Implantable Continuous Glucose Sensors
Volume: 4 Issue: 3
Author(s): Eric Renard
Affiliation:
Keywords: Diabetes mellitus, Continuous blood glucose monitoring, Glucose sensors, Implantable devices, Closed-loop insulin delivery
Abstract: Because of the limits of wearable needle-type or microdialysis-based enzymatic sensors in clinical use, fully implantable glucose monitoring systems (IGMS) represent a promising alternative. Long-term use reducing impact of invasiveness due to implantation, less frequent calibration needs because of a more stable tissue environment around the sensor and potential easier inclusion in a closed-loop insulin delivery system are the expected benefits of IGMS. First experiences with subcutaneous and intravenous IGMS have been recently collected in pilot studies. While no severe adverse events have been reported, biointerface issues have been responsible for the failures of IGMS. Tissue reactions around implanted subcutaneous devices and damages of intravenous sensors due to shearing forces of blood flow impaired IGMS function and longevity. In functioning systems, accuracy of glucose measurement reached satisfactory levels for average durations of about 120 days with subcutaneous IGMS and 259 days with intravenous sensors. Moreover, sensor information could help to improve time spent in normal glucose range when provided to patients wearing subcutaneous IGMS and allowed safe and effective closed-loop glucose control when intravenous sensors were connected to implanted pumps using intra-peritoneal insulin delivery. These data could open a favourable perspective for IGMS after improvement of biointerface conditions and if compatible with an affordable cost.
Export Options
About this article
Cite this article as:
Renard Eric, Implantable Continuous Glucose Sensors, Current Diabetes Reviews 2008; 4 (3) . https://dx.doi.org/10.2174/157339908785294406
DOI https://dx.doi.org/10.2174/157339908785294406 |
Print ISSN 1573-3998 |
Publisher Name Bentham Science Publisher |
Online ISSN 1875-6417 |
Call for Papers in Thematic Issues
Advancing Diabetic Wound Healing: Mechanisms and Interventions
In recent years, diabetic wounds have become a global health concern with an increase in the incidence of diabetes. Diabetic wounds are a kind of chronic and refractory ulcer. It is generally due to microcirculatory disturbances and reduced levels of endogenous growth factors. Delayed cutaneous wound healing is a chronic ...read more
Advancing Insights into Type 1 Diabetes: From Mechanisms to Management
Type 1 diabetes (T1D) represents a significant global health challenge, requiring a deep understanding of its complex pathophysiology and the development of innovative strategies for prevention, treatment, and management. This thematic issue highlights the latest progress in understanding the autoimmune processes underlying T1D, advances in beta-cell biology, and novel therapeutic ...read more
Exerscience: management of diabetes by physical activity/exercise
Physical activity/exercise is key to the management of diabetes and its complications. Studies have suggested that increased physical activity or regular exercise is associated with reduced risks of diabetes and its complications. However, challenges remained on how to promote physical activity or exercise efficiently, e.g., increase the adherence to physical ...read more
Next-Generation Drug Delivery Systems for Diabetes: Nanoparticles, Hydrogels, and Phytosome Technologies
This thematic issue, titled "Next-Generation Drug Delivery Systems for Diabetes: Nanoparticles, Hydrogels, and Phytosome Technologies," will focus on advanced formulation science to enhance diabetes treatment. It covers innovative platforms such as nanoparticles, responsive hydrogels, and phytosome technologies for improving the bioavailability, stability, and precision in delivering antidiabetic agents. Key areas ...read more

- Author Guidelines
- Bentham Author Support Services (BASS)
- Graphical Abstracts
- Fabricating and Stating False Information
- Research Misconduct
- Post Publication Discussions and Corrections
- Publishing Ethics and Rectitude
- Increase Visibility of Your Article
- Archiving Policies
- Peer Review Workflow
- Order Your Article Before Print
- Promote Your Article
- Manuscript Transfer Facility
- Editorial Policies
- Allegations from Whistleblowers
- Announcements
Related Articles
-
Therapeutic Approaches for Reducing C-Reactive Protein (CRP) Levels and the Associated Cardiovascular Risk
Current Chemical Biology Targeting Dyslipidemia in the Metabolic Syndrome: An Update
Current Vascular Pharmacology Open Questions on Gestational Diabetes Mellitus in Twin Pregnancies
Current Diabetes Reviews Pitavastatin and 4-Hydroxy-3-Methoxyacetophenone (HMAP) Reduce Cognitive Dysfunction in Vascular Dementia During Experimental Diabetes
Current Neurovascular Research Adherence to Treatment, Arterial Stiffness and Cognitive Function in Irbesartan- Treated Newly Diagnosed Hypertensive Patients
Current Vascular Pharmacology Anatomical and Functional Relationships Between Sensory Nerves and Mast Cells
Anti-Inflammatory & Anti-Allergy Agents in Medicinal Chemistry Insulin Resistance and Polycystic Ovary Syndrome Through Life
Current Pharmaceutical Design Genetics and Genomics Interventions for Promoting Millets as Functional Foods
Current Genomics In Vivo Hypoglycemic Studies of Polyherbal Phytoceuticals, Their Pharmacokinetic Studies and Dose Extrapolation by Allometric Scaling
Current Drug Discovery Technologies Effects of Combining Linagliptin Treatment with BI-38335, A Novel SGLT2 Inhibitor, on Pancreatic Islet Function and Inflammation in db/db Mice
Current Molecular Medicine Neuroretinal Apoptosis as a Vascular Dysfunction in Diabetic Patients
Current Neuropharmacology Paliperidone Use in the Elderly
Current Drug Safety Application of In Vivo Animal Models to Characterize the Pharmacokinetic and Pharmacodynamic Properties of Drug Candidates in Discovery Settings
Combinatorial Chemistry & High Throughput Screening Exploring Shared Pathogenesis of Alzheimer’s Disease and Type 2 Diabetes Mellitus via Co-expression Networks Analysis
Current Alzheimer Research Microparticles in Health and Disease: Small Mediators, Large Role?
Current Vascular Pharmacology Telmisartan Promotes Potential Glucose Homeostasis in Stroke-Resistant Spontaneously Hypertensive Rats via Peroxisome Proliferator-Activated Receptor γ Activation
Current Neurovascular Research Biochemical Markers of Renal Function
Current Medicinal Chemistry The GH/IGF-1 Axis in Chronic Heart Failure
Endocrine, Metabolic & Immune Disorders - Drug Targets The Role of Oestrogen Receptor Beta (ERβ) in the Aetiology and Treatment of Type 2 Diabetes Mellitus
Current Diabetes Reviews Impact of Pre-existing Kidney Dysfunction on Outcomes Following Transcatheter Aortic Valve Replacement
Current Cardiology Reviews